For hospitals Laboratory

Hospital laboratory software (LIS)

Track every sample, check results before release, alert a doctor about critical values, and block results from an analyser that failed QC.

The lab quality control workbench: a Levey-Jennings chart with Westgard rule checks and open violations.
The QC workbench.
What it does

Laboratory software for a hospital lab. Track every sample, check and release results, and make sure a dangerous result reaches a doctor. Daily quality control stops results from a failed analyser going out.

Who uses it

Lab technicians, who collect and run samples. Pathologists and lab managers, who check and release results. Doctors and nurses, who must hear about a critical result fast.

The problem in an Indian hospital

What this fixes

๐Ÿงช

Samples go missing

Nobody can say if a sample was collected, received or is still waiting.

๐Ÿšจ

A critical result sits unread

A dangerous potassium value is printed on a report that nobody opens for hours.

๐Ÿ“‰

QC done on paper

The daily control run is written in a register, and a failed run does not stop anything.

โœ…

Results released unchecked

A result goes out before the right person has checked it.

What you get

What the laboratory screens do

Every sample, every step

Track each sample from pending to collected, in process, resulted, verified and delivered. Each step records the time and who did it.

Reject and redraw

Reject a sample with a reason. Redraw it as a new sample, linked to the one it replaces.

Check before release

Critical results are listed first. Every value sits next to its normal range and its critical range. Only authorised staff can verify; nurses cannot.

Critical value alerts

When a critical result is verified, an alert is raised by itself. It goes to the treating doctor first, and moves to the next person if nobody acknowledges in time.

Call and read-back log

Log who was called, who received the call, when, and whether the value was read back. Print the critical value register as a PDF.

QC workbench and analyser monitor

Record control runs and see them on a Levey-Jennings chart with Westgard rule checks. Record the root cause and fix. See each analyser and its open problems on one screen.

๐Ÿ”’

A failed QC run blocks release

If a control run breaks a Westgard rule set to block, that analyser is locked. Results from that analyser cannot be released until the lab records the fix and lifts the lock. The screen shows why a result is blocked. The lock covers results that come in from a connected analyser; results typed in by hand are not linked to an analyser.

How it connects

Part of one hospital system

Every module works on the same patients, admissions and beds. Nothing is typed twice. See the related modules:

Questions

Questions about laboratory

How does a critical value alert work?

When a result with a critical value is verified, the system raises an alert by itself. It goes to the treating doctor first. If nobody acknowledges it in time, it moves to the next person on the list. Staff then log the phone call and the read-back.

Who can verify and release results?

Only staff with the right permission, such as the lab manager or a doctor. Nurses can view results but cannot verify them.

What does the QC workbench do?

You record each control run. The system plots it on a Levey-Jennings chart, checks the Westgard rules, and asks for the root cause and the fix when a rule is broken.

Can a rejected sample be collected again?

Yes. Reject it with a reason, then redraw it. The new sample gets its own number and stays linked to the old one.

See laboratory on your own wards

Book a demo. We set up OPD Suite for your hospital with you, and show you this module first.